Rat Clara Cell Secreted Protein (CCSP) ELISA Kit
Rat Clara Cell Secreted Protein (CCSP) ELISA Kit (Used in serum, plasma, cell culture supernatant and other biological fluids) principle This experiment uses the double antibody sandwich ABC-ELISA method. Coated with anti-rat CCSP monoclonal antibody on the enzyme plate, the standard and sample CCSP combined with monoclonal antibody, add biotinylated anti-rat CCSP to form an immune complex connected to the plate, horseradish peroxidation The enzyme-labeled Streptavidin is combined with biotin, the substrate working solution is added, and the final solution is added with sulfuric acid. The OD value is measured at 450nm. The CCSP concentration is proportional to the OD value. The CCSP in the specimen can be obtained by drawing a standard curve concentration. Kit composition (stored at 2-8 ° C) Coated Wells 96 wells Enzyme Conjugate 12ml 10 × Sample Buffer 12ml 20 × concentrated washing solution (Wash Buffer) 50ml Standards (Standards): 2000ng / bottle 2 bottles Substrate working solution (TMB Solution) 12ml The first antibody working solution (Biotinylated Antibody) 12ml Stop Solution (Stop Solution) 12ml Prepare reagents and collect blood samples 1. Collect specimens: serum, plasma (EDTA, citrate, heparin anticoagulation), cell culture supernatant, tissue homogenate, etc. as soon as possible, stored at 2-8 ℃ for 48 hours; longer time must be frozen (-20 ℃ Or -70 ℃), avoid repeated freezing and thawing. 2. Standard solution preparation: Add 2ml of distilled water to mix well before use to make a solution of 1000ng / ml. Set 8 standard tubes, add 900ul of sample dilution in the first tube, and 500ul of sample dilution in the second to eighth tubes. Add 100 ul of standard solution of 1000 ng / ml to the first tube and mix it, then aspirate 500 ul with the sampler and move to the second tube. Repeat the dilution in this manner repeatedly, draw 500ul from the seventh tube and discard it. The eighth tube is a blank control. 3. The 10 × specimen dilution is diluted 1:10 with distilled water (example: 1ml concentrated dilution + 9ml distilled water). 4. Washing solution: 1:20 dilution with redistilled water (example: 1ml concentrated washing solution is added with 19ml of redistilled water) Testing procedures 1. Add sample: add 100ul of standard or sample to be tested to each well, mix the reaction plate thoroughly and place at 37 ℃ for 120 minutes. 2. Wash the plate: wash the reaction plate 4-6 times with the washing solution, and print it on the filter paper. 3. Add 100ul of the first antibody working solution to each well. The reaction plate was mixed thoroughly and then placed at 37 ° C for 60 minutes. 4. Wash board: same as above. 5. Add 100ul of enzyme-labeled antibody working solution to each well. Place the reaction plate at 37 ° C for 30 minutes. 6. Wash board: same as above. 7. Add 100ul of substrate working solution to each well, and place in a dark place at 37 ℃ for 15 minutes. 8. Add 100ul of stop solution to each well and mix well. 9. Measure absorbance at 450nm with a microplate reader within 30 minutes. Result calculation and judgment 1. All OD values ​​should be calculated after subtracting the blank value. 2. With the standard products 100, 50, 25, 12.5, 6.2, 3.1, 1.56, 0 ng / ml as the abscissa and the OD value as the ordinate, draw a graph on the graph paper and draw a standard curve. 3. Find the corresponding CCSP content on the graph according to the OD value of the sample. Kit performance 1. Sensitivity: The minimum detection concentration of CCSP is less than 1ng / ml. 2. Specificity: Recombinant or natural rat CCSP can be detected simultaneously. Does not cross-react with other cytokines in rats. 3. Repeatability: The coefficient of variation within the board and the board is less than 10%. Precautions 1. The above standard holes and samples to be tested are recommended to be re-holes, and the standard curve should be made at the same time for each measurement. 2. The washing process is critical. Insufficient washing will lead to an increase in accuracy error and OD value. 3. After opening the slats, the remaining slats should be sealed again to keep the slats dry. 4. This kit should be stored in a 4oC refrigerator. 5. This kit is for scientific research only, not for clinical diagnosis!
Microfiber Flat Mops all produced by 80% poyester and 20% polyamide microfiber mop fabrics.With finished style with banding edge and stitching edge,and very easy to attached with mop frmae with loop and hook velcro.Washable more than hundreds times.Commercial than tradional cotton mop.You can clean al kinds of floor surface with only water.
Microfiber Flat Mop,Flat Squeeze Mop,Flat Mop Pads,Flat Squeeze Mop And Bucket
jiangsu qiyun cleaning knitting product co.,ltd , https://www.jarfrry.com